AP200-LM-400
LoRa Master /Modbus RTU Client Agent, Group IO Mapping, Logic Rule, 410~493 Mhz by software configuration (Must work with AP144-LC) (with LoRa antennas)
Términos y condiciones
30-day money-back guarantee
Shipping: 2-3 Business Days
The AP200-LM/AP144-LC utilizes the latest Low Power Wide Area (LPWA) technology to build Modbus/RTU communication for long-distance, wide-coverage, and low power consumption wireless IoT applications. Multiple analog inputs and outputs are supported in AP144-LC, such as voltage inputs and outputs, current inputs and outputs, PWM output and one RS-485 port for Modbus RTU slave. One AP200-LM can connect up to 250pcs AP144-LC LoRa end nodes for two-way communications where field site analog signals are sent from AP144-LC and mirrors to another AP144-LC by AP200-LM. The LoRa wireless distance can reach up to 3-6KM distance depending on the environment. The AP200-LM/AP144-LC offers great flexibility in wireless IoT applications, such as LED light control without cable , Analog signal reproduced at remote site to replace traditional wiring.
Product Features:
Analog I/O Extension & Tracking by LoRa
(AP144-LC+AP200-LM)
・Transparent /Reproduce Analog Signal by LoRa
・AP200-LM Polling Source AP144-LC specific Channel and Output to Target AP144-LC specific Channel
・Create /Edit Tracking Rule by Utility Tool
・Achieve 2-Sites Analog Tracking
V / V, V / A, A / A Auto I/O Tracking
(AP144-LC + AP200-LM)
・V / V Tracking – Local Input Voltage , Remote Output Voltage
・V / A Tracking – Local Input Voltage, Remote Output Current in V/A Ratio
・A / A Tracking – Local Input Current, Remote Output Current
・A / V Tracking – Local Input Current , Remote Output Voltage in A/V Ratio
・20 I/O Rule Entries (Maximum)
Secured & Reliable Radio Communication
・ECHO & Re-Send Mechanism
・AES 128 Data Encryption
Windows© Configure Tools
・User-Friendly, Model Auto Detection
・Analog IO Parameter Read and Write
・On-Line Monitoring, Log File Download
・Micro-USB Interface
4~20mA Input / Output (AP144-LC)
・2 Channels Current Sensing, 0.3%High Accuracy
・1 Channel Current Output, 0.3% High Accuracy
Event Log & Utility Monitoring (AP200-LM)
・1K Event Log Entries – Polling Fail, Remote Control Fail
・On-Line Monitoring by Utility
Industrial Application
・10~30V DC wide power range input
・Low Power Consumption
・Wide Coverage up to 6KM
・Max.250 AP144-LC Nodes to one AP100-LM
・-40 ~ 75°C / 90%H Operating Temperature / Humidity
・Compliance IEC 61000-6-2/-6-4 Heavy Industrial EMC